Subject: Ottar Kvindesland wrote: > > Dear OM, > I got your e-mail adress through a News Group. > > Could you suggest a procedure to set the europeean frequencies and > 1750 Hz tone in the Kenwood TS-790A ? > > 73 de Ottar LA9IHA >
The manual shows the following boards to be different:
IF Unit X44-3060 430mhz
| US Model | E Model | |
| C209 | 2p | 1.5p |
| C215 | 1p | 2p |
| C322 | X | 0 --- 33p |
| R216 | 0 | X |
| L248 | 0 | W211 |
0= Used
X= Not Used
IF Unit
| Us Model | E Model | |
| R335 | 33k | 150k |
| R336 | 0 | X |
| C432 | X | 0 --- 470p |
| C574 | 0 | X |
| C575 | 0 | X |
0= Used
X= Not Used
Control Unit
You might try jumpering it for the E model and see what happens. I didn't study the schematic to see what all the changes really did.
| US Model | E Model | |
| D21 | X | 0 |
| D22 | 0 | X |
| D23 | X | 0 |
| D24 | X | 0 |
X= Not used
0= Used
Clif